• HPC-2000 Level Controller Digital Display Pressure Switch Axial Mounted Relay Output Replaces Electric Contact Meter Sensor
  • HPC-2000 Level Controller Digital Display Pressure Switch Axial Mounted Relay Output Replaces Electric Contact Meter Sensor
  • HPC-2000 Level Controller Digital Display Pressure Switch Axial Mounted Relay Output Replaces Electric Contact Meter Sensor
  • HPC-2000 Level Controller Digital Display Pressure Switch Axial Mounted Relay Output Replaces Electric Contact Meter Sensor
  • HPC-2000 Level Controller Digital Display Pressure Switch Axial Mounted Relay Output Replaces Electric Contact Meter Sensor
  • HPC-2000 Level Controller Digital Display Pressure Switch Axial Mounted Relay Output Replaces Electric Contact Meter Sensor

HPC-2000 Level Controller Digital Display Pressure Switch Axial Mounted Relay Output Replaces Electric Contact Meter Sensor

Type: Double Flange Differential Pressure
Contact: Contact
Output Signal Type: Switching Type
Production Process: Integration
Feature: Low Temperature Resistant
Material: Plastic
Samples:
US$ 50/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2023

Suppliers with verified business licenses

Guangdong, China
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 15 days
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (12)
  • Overview
  • Product Description
  • Product Parameters
  • Product advantage
  • Product Display
  • Product Size
  • Attention
  • Our Advantages
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
HPC-2000
IP Rating
IP65
Certification
CE
Customized
Customized
Measurement Accuracy
0.1~0.5%Fs
Measuring Range
0-200MPa
Transport Package
Package
Specification
silver
Trademark
ZEIHOU
Origin
China

Product Description

Product Description

HPC-2000 Level Controller Digital Display Pressure Switch Axial Mounted Relay Output Replaces Electric Contact Meter Sensor

1. The company's products are special customized products
2. The price of this product is for reference only
3. To purchase products, contact customer service to provide specific parameter selection
Product Parameters
 
Model: HPC-2000 Pressure form: gauge pressure, absolute pressure
Range: 0~5, 100, 500, 800, 1000 Kpa 0~2, 10, 60, 120 Mpa
Output signal: Relay, MODBUS, analog, digital output optional Display mode: 4-bit LED display
Accuracy (%FS) : 0.25-0.5 Nonlinearity (%FS) : ≤ 0.2 / ≤0.5
Regression lag (%FS) : ≤ 0.2 / ≤0.5 Zero temperature drift (%FS/°C) : ≤0.1
Full degree temperature bleaching (%FS) : ≤ 0.02 Operating voltage (V) : 12-36VDC
Ambient temperature (°C) : -20~60C Overload capacity (%) : 200
Life: <90 million pressure cycles (25°C) Load resistance (Q) : ≤750
Response time (ms) : ≤0.1 Measuring media: Various media compatible with 316L
Diaphragm material: 316L or ceramic diaphragm Interface thread: M20*1.5 or custom
Joint material: 304, 316, titanium material, PTFE Protection class: IP65
Product advantage

HPC-2000 Level Controller Digital Display Pressure Switch Axial Mounted Relay Output Replaces Electric Contact Meter Sensor

Product Display

HPC-2000 Level Controller Digital Display Pressure Switch Axial Mounted Relay Output Replaces Electric Contact Meter Sensor

Product Size

HPC-2000 Level Controller Digital Display Pressure Switch Axial Mounted Relay Output Replaces Electric Contact Meter Sensor

Attention
 
  1. Prohibit measuring media that are incompatible with the transmitter material
  2. Ensure that the power supply voltage meets the product requirements and wire according to the instructions
  3. Install the transmitter in a ventilated and dry place to avoid direct exposure to strong light and rain
  4. Pay attention to using snake skin pipes or iron pipes to protect the outgoing cables, or raise the cable rack
  5. It is recommended to power on for at least 10 minutes to achieve optimal product performance
  6. When disassembling the transmitter, ensure that the pressure source is turned off to prevent the medium from spraying out
  7. This product is not explosion-proof and can cause major accidents when used in explosion-proof areas
Our Advantages

HPC-2000 Level Controller Digital Display Pressure Switch Axial Mounted Relay Output Replaces Electric Contact Meter Sensor

HPC-2000 Level Controller Digital Display Pressure Switch Axial Mounted Relay Output Replaces Electric Contact Meter Sensor

 HPC-2000 Level Controller Digital Display Pressure Switch Axial Mounted Relay Output Replaces Electric Contact Meter Sensor
Packaging & Shipping

HPC-2000 Level Controller Digital Display Pressure Switch Axial Mounted Relay Output Replaces Electric Contact Meter Sensor

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
500000 RMB
Plant Area
101~500 square meters